Overall Height 26.5" (673mm)
Overall Width 30" (762mm)
Overall Depth 23.875" (607mm)
Depth from Cabinet 4.25" (108mm)
With Door Open 17.50" (445mm)
Cavity Height 12.00" (305mm)
Cavity Width 24.00" (610mm)
Cavity Depth 15.00" (381mm)
Weight 230 lbs. (105 kg.)
 
Oven Cavity
Height 12.00" (305mm)
Width 24.00" (610mm)
Depth 15.00" (381mm)
Cooking Space 2.5 cu. ft.
   
Electrical Specifications
Phase Single
Frequency 60 Hz
Current 30 Amp
Cord 4-wire (inc. ground)
Voltage 208 VAC (TD030-*-208)
240 VAC (TD030-*-240)
*Denotes color in model number
Connection
(See note 3)
5.5-6.5 foot flex conduit
Total Connected Power
(See note 4)

30 Amp
Wall Installations
Opening Height 25"
Opening Width 28.25"
Cabinet
Width (min) 30" (762mm)
Wood Fascia Thickness (min) .375" (10mm)
Rough Wall Opening
Height (min/max) 25.125" (638mm)
Width (min/max) 28.5" (726mm)
Upper Corner Radius (preferred) .5" (13mm) (13mm)
Minimum Depth 24.00" (610mm)
   
Cabinet Base Height
Wall Installations (min) 34.75" (883mm)
Wall Installations (max) (984mm) 38.75"
Under Counter Installations (min) 5.5" (139mm)
   


NOTE:
1. "*"Indicates a two letter code - OR, RD, BU, CH, IV, WH, or SS - which refers to the oven door color.

2. Dimensions in parentheses are in millimeters unless otherwise noted.

3. Unit includes a 5/12 foot flex conduit to be used between the oven and conduit box. Connectors are supplied by installation electrician.

4. Branch circuit must be protected with a 50 Amp (Double Wall Oven) or 30 Amp (Single Wall Oven) over-current protector.

5. Failure to adhere to the Rough Wall Opening specs may cause corners of the cabinet opening to be exposed.

6. Due to the frame's overall depth the power supply line location shown in the illustrations (high or low conduit box) must be adhered to in order to obtain a proper fit in the cabinet.

7. Cabinet base must be built to support the oven's weight. TurboChef strongly recommends a solid base.

8. The oven utilizes ambient air from the kitchen to assist in keeping the operational components cool. This air is drawn in through the top control panel area through openings in the top access panel and exhausted through an opening at the base of the oven. Please allow a 1-inch minimum clearance above and below these areas.



Cabinet Measurements

Get the TurboChef SpeedCook Oven installation instructions.

Click Here (PDF, 675K)



Fig. 1
A. 24" minimum (610mm)



Fig. 2
A. 28.5" (724mm)
B. 26.125" (664mm)
C. 30" (762mm)
D. 34.75" (883mm)
E. 25.125" (639mm)

1. Recommended drill hole location if conduit box (electrical outlet) is high

2. Recommended drill hole location if conduit box (electrical outlet) is low

Bottom Edge